首页> 外文会议>North American Mine Ventilation Symposium >LALOR MINE: IMPACTS AND IMPLICATIONS OF A 2,500 HP MAIN EXHAUST FAN FAILURE
【24h】

LALOR MINE: IMPACTS AND IMPLICATIONS OF A 2,500 HP MAIN EXHAUST FAN FAILURE

机译:Lalor矿:2500马力主流风扇故障的影响和影响

获取原文

摘要

In June, 2018 Lalor Mine experienced a catastrophic blade failure of its No. 2 main exhaust fan. Over the following weeks several key changes were made to the auxiliary ventilation system to allow for continued production while the exhaust fans were repaired. Issues encountered during the period of reduced ventilation, and how they were addressed, are analyzed. The suspected causes of the exhaust fan blade failure and how risk was mitigated during the reconstruction are discussed. Key findings and lessons learned are summarized.
机译:2018年6月,2018年Lalor Mine经历了2号主排气扇的灾难性叶片。 在接下来的几周内,对辅助通风系统进行了几个关键变化,以允许在排气扇修复时继续生产。 分析了通风的减少期间遇到的问题,以及如何解决它们。 讨论了排气扇叶片破坏的疑似原因以及在重建期间如何减轻风险。 概述了主要的调查结果和经验教训。