The objective of this paper is to analyze the safe operating area limitation caused by dynamic current localization at the gate turn-off transient of thyristor-like bipolar devices with imperfectly coupled elementary cells. The impact of series gate resistance on switching characteristics is studied by numerical simulation for the typical case of integrated thyristor with external MOS-control. The inequality of gate resistances for different cells is found to cause dangerous current localization and subsequent failure at the turn-off operation. Quantitative thresholds for the onset of current localization are determined and compared for different possible turn-off modes of the device under study.
机译:本文的目的是分析由晶闸管状双极器件的闸门关闭瞬态的动态电流定位引起的安全操作面积限制,其具有不完全耦合的基本细胞。用外部MOS控制的集成晶闸管的典型案例研究了串联栅极电阻对开关特性的影响。发现不同电池的栅极电阻不等式,导致危险的电流定位和随后的关闭操作失效。确定电流定位发作的定量阈值,并比较在研究中的装置的不同可能的关闭模式。