Fibre Optic Distributed Temperature Sensing (DTS) methods have been successfully applied to many processes in the oil & gas industry. This non-intrusive sensing system proves invaluable in the monitoring of LNG pipelines both for cool down at commissioning, for temperature profiling during operation and as a leak detection system. There is ongoing work in the use of fibre optic DTS systems in the development of smart cryogenic hoses for the transfer of LNG and storage and piping systems aboard floating LNG vessels. Developments in LNG pipes include multi-layer insulated piping systems. This contribution presents recent studies in the use of fibre optic distributed sensors for temperature profiling and leak detection in multi-layer insulated LNG pipes. Industrial applications of fibre optic distributed temperature sensors (DTS) include the use of DTS systems as an early warning system, allowing operators to act swiftly in the event of a breach in LNG containment as a part of the safety management system as well as provide a real time temperature profiling during loading, offloading and cool down cycles. This paper also discusses a recently installed Safety Integrity Level 2 (SIL 2) rated leak detection system based on fibre optic distributed temperature sensing (DTS) method in a UK LNG importation plant.
机译:光纤分布式温度传感(DTS)方法已成功应用于石油和天然气行业的许多过程。这种非侵扰性传感系统证明在监测LNG管道时,用于在调试期间进行冷却,用于在操作期间的温度分析和泄漏检测系统。在使用光纤DTS系统方面存在持续的工作,以便在浮动LNG血管的转移液体和储存和管道系统的转移中进行智能低温软管。 LNG管道的开发包括多层绝缘管道系统。该贡献在使用光纤分布式传感器的使用中提供了最近的研究,用于在多层绝缘LNG管中进行温度分布和泄漏检测。光纤分布式温度传感器(DTS)的工业应用包括使用DTS系统作为预警系统,允许运营商在LNG遏制中作为安全管理系统的一部分违反违规行动,以及提供a加载,卸载和冷却循环期间的实时温度分析。本文还讨论了英国LNG进口厂光纤分布式温度传感(DTS)方法的最近安装的安全完整级别2(SIL 2)额定泄漏检测系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号