In this paper, the oscillatory response in conductance of a platinum coil based sensor is reported. The Pt coils with different turns were constructed and tested in air environment containing carbon monoxide. Reproducible conductance oscillations were found under a certain range of operating currents. Within this current region, the range of CO concentrations over which oscillations appeared increased as the testing current increased. The lowest CO concentration at which oscillations were observed was 150ppm. By comparing sensor responses obtained in synthetic and ambient air, it was concluded that water vapor has an influence on oscillations and increases the frequency.
机译:本文报道,报道了铂基线圈传感器的电导振荡响应。具有不同转弯的PT线圈在含有一氧化碳的空气环境中构建和测试。在一定范围的操作电流下发现可重复的电导振荡。在该电流区域内,随着测试电流增加而增加振荡的CO浓度的范围。观察到振荡的最低Co浓度为150ppm。通过比较合成和环境空气中获得的传感器响应,得出结论,水蒸气对振荡产生影响并增加频率。