首页> 外文会议>The International Conference Exhibition on Liquefied Natural Gas >IMPROVEMENT OF HIGH HEATING VALUE OF COMMERCIALISED LIQUEFIED NATURAL GAZ OF GL1Z PLANT BY OPTIMISING THE LPG EXTRACTION AMELIORATION DU POUVOIR CALORIFIQUE SUPERIEUR DU GAZ NATUREL LIQUEFIE DU COMPLEXE GL1Z EN OPTIMISANT LA RECUPERATION DES GPL
【24h】

IMPROVEMENT OF HIGH HEATING VALUE OF COMMERCIALISED LIQUEFIED NATURAL GAZ OF GL1Z PLANT BY OPTIMISING THE LPG EXTRACTION AMELIORATION DU POUVOIR CALORIFIQUE SUPERIEUR DU GAZ NATUREL LIQUEFIE DU COMPLEXE GL1Z EN OPTIMISANT LA RECUPERATION DES GPL

机译:通过优化GPL回收,优化热轧型优质液体GL1Z天然气的LPG提取改善GL1Z植物商业化液化天然气高加热值的提高

获取原文

摘要

During recent years, the quality of the feed natural gas to the liquefied natural gas plant GL1Z has become leaner in heavy hydrocarbons. Leaner feed gas makes it increasingly difficult to obtain the required propane and butane to be recycled to the scrub tower. This has led to long start up times to stabilise the scrub tower operation and sometimes causes certain instabilities even during normal operation. To overcome these problems, a LPG recovery heat exchanger, using multi-component refrigerant as a cooling medium has been installed in the scrub tower overhead circuit. With the addition of this exchanger downstream of the scrub tower condenser, LPG recycle to the scrub tower is not required to achieve the scrub tower overheads specification. However, a decrease of the high heating value of the commercialised LNG, and an overload of the fractionation unit have been experienced. As a solution, the initial operating temperature of the LPG recovery heat exchanger has been increased, in order to improve the high heating value of the commercialised LNG product. The objective of this paper is to share, with the LNG 14 Conference participants, the GL1Z plant experience in operating the LPG recovery heat exchanger, hoping that this may be beneficial for similar LNG plants modifications elsewhere.
机译:近年来,饲料天然气对液化天然气植物GL1Z的质量变得更加富含碳氢化合物。更精简的饲料气体使得获得所需的丙烷和丁烷越来越难以被再循环到磨砂塔上。这导致了长时间的开始,以稳定磨砂塔操作,即使在正常操作期间也会导致某些不稳定性。为了克服这些问题,使用多组分制冷剂作为冷却介质的LPG回收热交换器已经安装在磨砂塔架空电路中。随着磨砂塔冷凝器下游的该交换器,LPG回收到擦洗塔不需要实现磨砂塔架总规范。然而,已经经历了商业化LNG的高加热值和分馏单元的过载降低。作为解决方案,LPG回收热交换器的初始操作温度已经增加,以提高商业化LNG产品的高加热值。本文的目的是与LNG 14会议参与者分享GL1Z植物在操作LPG回收热交换器方面的经验,希望这对其他地方的类似LNG植物进行了有益。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号