Partial-Overlap Biocular Image Misalignment Tolerance

机译:部分重叠的生物图像未对准耐受性

获取原文

摘要

Partial-overlap biocular helmet-mounted display (HMD) design flexibility and cost are directly related to image misalignment standards. Currently suggested standards are based on highly variable data from a number of studies, most using subjective discomfort or diplopia measures. This study tested the suggested standard for divergent horizontal image misalignment in a partial-overlap biocular optical system by exercising vigilance performance during image misalignment. Also, pre- and post-image misalignment divergence, convergence and heterophoria measurements were taken. The results revealed that clinical visual diagnoses, associated with accommodation and vergence, were clearly related to vigilance task performance, showing a greater number of vigilance errors for subjects viewing misaligned displays. In-device post-image misalignment divergence recovery and convergence break-recovery were significantly decreased. This was not found for the no-offset controls.
机译:部分重叠的生物盔甲安装显示器(HMD)设计灵活性和成本与图像未对准标准直接相关。目前建议的标准基于来自许多研究的高度变量数据,最大限度地使用主观的不适或复视措施。该研究通过在图像未对准期间锻炼警惕性表现,测试了在部分重叠的生物光学系统中的发散水平图像未对准的建议标准。此外,还采用了图像前和图像后未对准性分歧,收敛性和异硬体测量。结果表明,与住宿和痛苦相关的临床视觉诊断明显与警惕任务表现有关,对观看未对准显示的主题显示更多的警惕性错误。图像内部图像后图像未对准分歧恢复和收敛断裂恢复显着降低。没有找到No-Offset控件。