【24h】

Fire performance of steel portal frame buildings

机译:钢门户框架建筑物的火灾性能

获取原文

摘要

This paper describes a study into the fire behaviour of steel portal frame buildings at elevated temperatures using the finite element programme SAFIR. The finite element analysis carried out in this report is three dimensional and covers different support conditions at the column bases, the presence of axial restraints provided by the end walls, several different locations and severities of fires within the building, different levels of out-of-plane restraint to the columns and the effect of concrete encasement to the columns. From a large number of analyses, it is shown that the bases of the steel portal frames at the foundations must be designed and constructed with some level of base fixity to ensure that the structure will deform in an acceptable way during fire, with no outwards collapse of the walls. The analyses also showed that it is not necessary for steel portal frame columns to be fire-protected unless the designer wishes to ensure that the columns and the wall panels remain standing, during and after the fire.
机译:本文介绍了使用有限元计划Safir在升高的温度下钢门框架建筑物的火灾行为的研究。本报告中进行的有限元分析是三维,涵盖柱碱基的不同支撑条件,由末端壁提供的轴向束缚,几个不同的位置和建筑物内火灾的猛烈性,不同水平的外-Plane抑制柱子和混凝土封装对柱的影响。从大量的分析中,结果表明,基础上的钢门户框架的基座必须设计和构造,以某种级别的基础固定度,以确保结构在火灾中以可接受的方式变形,没有外部崩溃墙壁。分析还表明,除非设计师希望确保柱子和墙板仍然站立,在火灾期间和之后,否则钢门户框架柱不需要被释放出射击。