首页> 外文会议>International symposium on reactor dosimetry >French PWR Vessel Surveillance Program Dosimetry: Experience Feedback from More than a Hundred Capsules
【24h】

French PWR Vessel Surveillance Program Dosimetry: Experience Feedback from More than a Hundred Capsules

机译:法国PWR船监控程序剂量测定:经验从一百多粒胶囊的反馈

获取原文

摘要

Fifty-eight PWR plants grouped in four standardized series are in operation in the Electricite de France (EDF) reactor pool. About 140 surveillance capsules were extracted and the associated dosimetric analysis carried out according to a defined and approved method described briefly. Taking one of the reactor series as example, the consistency of the results is presented and a comparison is made in terms of fluence with the results of the EFLUVE industrial code set up by EDF. A dosimetry processing improvement study is presented: it aims to take into account the modifications of the fuel management strategy implemented by EDF enabling the lifetime of the power plants to be extended. Finally the analysis of the approach adopted for determination of uncertainties and its improvement is explained.
机译:在四个标准化系列中分组的五十八种PWR植物在电器De France(EDF)反应堆池中运行。提取约140个监测胶囊,并根据简要描述的定义和批准的方法进行的相关剂量分析。考虑到其中一个反应堆系列作为示例,提出了结果的一致性,并根据EDF设置的EFLUVE工业代码的结果来进行比较。提出了一种剂量测定加工改进研究:它旨在考虑EDF实施的燃料管理策略的修改,从而能够延长发电厂的寿命。最后解释了确定不确定性和改进所采用的方法的分析。

著录项