首页> 外文会议>IEEE International Conference on Solid Dielectrics >Aging of Oil-impregnated Transformer Insulation Studied through Partial Discharge Analysis
【24h】

Aging of Oil-impregnated Transformer Insulation Studied through Partial Discharge Analysis

机译:通过局部放电分析研究了油浸式变压器绝缘的老化

获取原文

摘要

The aging of the epoxy-paper insulation of an oil-impregnated transformer was studied through partial discharge analysis. Accelerated electrical aging tests were carried out on samples of transformers windings, with and without paper insulation. Partial discharge (PD) measurements according to standard IEC 60270 were performed periodically during aging, and partial discharge phase patterns were recorded throughout the aging test. Some representative PD phenomena were obtained from the experimental results. The evolution of typical PD patterns is reported until breakdown.
机译:通过局部放电分析研究了油浸渍的变压器的环氧纸绝缘的老化。在变压器绕组的样品上进行加速电动老化试验,有和无纸质绝缘。根据标准IEC 60270的局部放电(PD)测量在老化期间定期进行,并且在整个老化测试中记录部分放电相位图。一些代表性PD现象是从实验结果获得的。报告典型PD图案的演变为击穿。