首页> 外文会议>Mexican Symposium on Medical Physics >Dosimetric Quality of Partially Loaded I-125 COMS Eye Plaques for Practical Placement on Posterior Tumors
【24h】

Dosimetric Quality of Partially Loaded I-125 COMS Eye Plaques for Practical Placement on Posterior Tumors

机译:部分加载的I-125 COMS斑块对后肿瘤进行实际放置的剂量测量

获取原文

摘要

Eye malignancies that are suitable candidates for low dose-rate brachytherapy have been treated using the Collaborative Ocular Melanoma Study (COMS) eye plaques with radioactive I-125 seeds at the University of Oklahoma Medical Center (OUMC). Partially loaded plaques are used to make surgical placement more convenient, especially for tumors that are posteriorly located. Over the past years, clinical cases have been performed using posterior loaded 16 mm plaques. In posterior loaded plaque cases, the prescription point is shifted off-axis towards the center of the actual seed distribution; this allows normalization of the dose to a desired depth and area of coverage. This study investigated the dosimetry of a 16 mm fully loaded eye plaque and partial loads equivalents (approximated) to 12 mm and 10 mm eye plaques with radioactive I-125, 6711 model seeds. The dose calculation agreement was assessed for two commercially used treatment plans and verified with film measurements. The standard treatment plans were calculated using the Nucletron Planning Systems (NPS) and compared with plans generated with Brachtherapy Planning 11.0.47 (Varian Medical Systems). Delivered doses were measured in water using Gafchromic EBT3 film. Doses at the prescription point as well as dose to points corresponding to critical structures were evaluated. The findings of this study reveal that calculated doses by NPS and Brachtherapy Planning are higher than measured doses for all distributions studied. Differences between NPS and Brachtherapy Planning were higher for off-axis prescription points. Differences in percent doses for low dose regions were comparable for both fully and posterior loaded plaques.
机译:使用俄克拉荷马大学医学中心(OUMC)的放射性I-125种子,对低剂量速率近距离放射治疗的眼部恶性肿瘤的眼睛恶性肿瘤已经治疗。部分装载的斑块用于使手术放置更加方便,特别是对于位于后面的肿瘤。在过去几年中,临床病例已经使用后部装入16毫米斑块进行。在后载斑块情况下,处方点朝向实际种子分布的中心移动;这允许剂量的标准化到所需深度和覆盖区域。该研究研究了16毫米完全加载的眼牙的剂量测定法和部分载荷等当量(近似)到12mm和10mm的眼斑,具有放射性I-125,6711模型种子。为两种商业使用的治疗计划评估剂量计算协议,并通过薄膜测量进行了验证。使用核棘轮规划系统(NPS)计算标准治疗计划,并与用颅治疗计划11.0.47(Varian Medical Systems)产生的计划进行比较。使用Gafchromic EBT3膜在水中测量递送剂量。评估处方点的剂量以及对应于关键结构的点的剂量。本研究的发现表明,NPS和颅脑疗法规划的计算剂量高于所研究的所有分布的测量剂量。偏离轴的处方点,NPS和BRACHTHERAPACY规划之间的差异更高。低剂量区域的百分点百分比对于完全和后部负载斑块的差异相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号