The Fine Print Note [FPN] No.1 in 2005 NEC Article 501.8 (B) [1] cautions users to "consider the temperature of internal and external surfaces that may be exposed to the flammable atmosphere" when putting a motor into service in a Class I,Division 2 environment.Thus it is critical that manufacturers and users of industrial electric motors understand that internal peak temperatures exceed the external peak temperatures.This paper presents three common IEEE 1349 [2] test methods used by manufacturers to determine these internal peak temperatures.Potential test method error and the test results from the three test methods are also presented.IEEE 1349 [2] provides only guidance when performing these test methods so this paper intends to provide additional clarification.The test motors presented in this paper are low voltage,AC induction,severe-duty,energy-efficient,TEFC motors commonly used in the "Petrochemical Industry".
机译:2005年NEC第501.8(b)第501(b)第501(b)第5条NO.1的精细印刷注释[1]注意者在将电动机放入服务中时,使用者“考虑可能暴露于易燃气氛的内部和外表面的温度” IS级,第2级环境.Thus,工业电动机的制造商和用户很重要,即内部峰值温度超过外部峰值温度。本文介绍了制造商使用的三个常见IEEE 1349 [2]测试方法来确定这些内部峰值温度。还介绍了三种测试方法的误差测试方法误差和测试结果。ieee 1349 [2]仅提供了在执行这些测试方法时提供的指导,因此本文旨在提供额外的澄清。本文提出的测试电机很低电压,交流诱导,严重,节能,常用于“石化工业”的TEFC电机。