首页> 外文会议>Chinese international conference on electrical machines >THREE-PHASE SYNCHRONOUS GENERATOR WITH DOUBLE-POLE INDUCED-EXCITATION (Ⅱ): CALCULATION OF THE ROTOR FIELD CURRENT WHEN HARMONICS ARE TAKEN INTO ACCOUNT
【24h】

THREE-PHASE SYNCHRONOUS GENERATOR WITH DOUBLE-POLE INDUCED-EXCITATION (Ⅱ): CALCULATION OF THE ROTOR FIELD CURRENT WHEN HARMONICS ARE TAKEN INTO ACCOUNT

机译:具有双极诱导激励的三相同步发电机(Ⅱ):考虑谐波时转子场电流的计算

获取原文

摘要

In double-pole induced-excitation synchronous generator, the rotor field current is a pulsating dc current which is induced in the rotor field coila by a stator dc exciting winding. In the paper, the expressions of the rotor field currents are deduced when harmonics are taken into account. Then the effects of harmonics on the rotor field current are discussed. The theoretical results are confirmed by tests.
机译:在双极诱导激励同步发电机中,转子场电流是通过定子直流励磁绕组在转子场线圈中被引导的脉动DC电流。在本文中,当考虑谐波时,推导出转子场电流的表达。然后讨论了谐波对转子场电流的影响。理论结果是通过测试确认的。