This paper presents the results of radon measurements carried out in and around Guru Nanak Dev University (GNDU) campus using SSNTD technique . The method used involved exposing small stripes of LR-115 Type II films in the bare mode . The estimated levels of radon and its progeny vary from 38.8 to 174.6 Bq/ m~3 and from 5.2 to 23.6 mWL respectively. For sake of comparison indoor radon measurements were also carried out using Alpha Guard and it has been observed that integrated measurements using plastic detectors gives higher values of radon concentration in the dwellngs.
机译:本文介绍了使用SSNTD技术在Guru Nanak Dev大学(GNDU)校园内和周围地区进行的氡测量结果。使用的方法涉及在裸模式下暴露LR-115型II型膜的小条纹。氡的氡和其后代水平分别从38.8至174.6 bq / m〜3和5.2〜23.6 mWL变化。为了进行比较,使用α保护还进行室内氡测量,并且已经观察到使用塑料检测器的集成测量在DWELLNG中提供更高的氡浓度值。