首页> 外文会议>IEEE Ultrasonics Symposium >Combined 2D Array Transducers/Deployment Kits for Real-Time 3D Ultrasound Guidance of Interventional Devices
【24h】

Combined 2D Array Transducers/Deployment Kits for Real-Time 3D Ultrasound Guidance of Interventional Devices

机译:组合2D阵列传感器/部署试剂盒,用于实时3D超声引导的介入设备

获取原文

摘要

We have described and fabricated 2D array transducers for many real-time volumetric imaging applications. These applications include transducers operating up to 7MHz for transthoracic imaging, up to 15MHz for intracardiac echocardiography (ICE), 5MHz for transesophageal echocardiography (TEE) and intracranial imaging, and 7MHz for laparoscopic ultrasound imaging (LUS). Now, we have developed a new generation of miniature 2D array transducers integrated into the deployment kits for interventional devices to enable real time 3D ultrasound scanning for improved guidance of minimally invasive procedures. We have constructed three new transducers. The first consists of 54 elements operating at 5MHz. Typical measured transducer element bandwidth was 25%, and the 50 Ohm round trip insertion loss was -65dB. Average nearest neighbor cross talk is -23.8dB. The second is a prototype 108 element 7MHz transducer. The transducer center frequency was actually 9MHz, with a -6dB bandwidth of 25%. The third is a prototype 108 element transducer operating at 5MHz. All transducers were constructed on a flat piece of copper clad polyimide and then wrapped around an 11 French catheter of a Cook Medical, Inc. vena cava filter deployment device. This creates the forward viewing ring array transducer. The elements are attached to the system imaging cable through W. L. Gore & Associates MicroMiniature Ribbon Cables. The interelement spacing is 0.2mm for the 54 element transducer, and 0.10mm for the two 108 element transducers.
机译:我们已经描述和制造了2D阵列传感器,用于许多实时体积成像应用。这些应用包括用于Transthoracic成像的换能器,对于Transthoracic成像,高达15MHz用于心膜膜内心动图(ICE),5MHz,用于过度异味超声心动图(TEE)和颅内成像,以及腹腔镜超声成像(LU)的7MHz。现在,我们开发了一代新一代的微型2D阵列传感器,集成到介入设备中的部署试剂盒中,以实现实时3D超声扫描,以改善微创手术的引导。我们建造了三个新的传感器。第一个由5MHz运行的54个元素组成。典型的测量换能器元件带宽为25%,50欧姆往返插入损耗为-65dB。平均最近的邻接串扰是-23.8db。第二是原型108元件7MHz换能器。换能器中心频率实际上是9MHz,带宽为-6dB带宽为25%。第三是在5MHz下操作的原型108元件换能器。所有传感器均由铜包覆的聚酰亚胺的平板上构建,然后缠绕在厨师医疗,Inc。vena cava过滤器部署装置的11个法国导管周围。这将创建前向查看环阵列传感器。该元件通过W. L. Gore&Commatiates带状丝带连接到系统成像电缆。对于54个元件换能器,间隙为0.2mm,两个108元件换能器为0.10mm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号