Axial compression ratio of Walls in Unreinforced Masonry Structures is studied based on a 7-story concrete small block building and a 7-story common brick building with FEM. Factors that influence the axial compression ratio are analyzed. The axial compression ratio of walls in unreinforced masonry structures is compared with that of walls in concrete shear wall structures and reinforced masonry structures. Besides, Characteristic value of axial compression ratio is calculated. The results shows that axial compression ratio ranges from 0.06 to 0.50 and is associated with story number, material, load, wall width and plane layout of structures etc. Characteristic value of axial compression ratio ranges from 0.04 to 0.30 which is about 60 percent of its design value.
机译:以一幢七层混凝土小砌块建筑和一幢七层普通砖混结构有限元为基础,研究了无筋砌体结构墙体的轴向压缩比。分析了影响轴向压缩比的因素。比较了非钢筋砌体结构中的墙的轴向压缩比与混凝土剪力墙结构和钢筋砌体结构中的墙的轴向压缩比。此外,计算了轴向压缩比的特征值。结果表明,轴向压缩比的范围为0.06〜0.50,与层数,材料,荷载,壁宽和结构平面布置等有关。轴向压缩比的特征值在0.04〜0.30的范围内,约为其压缩比的60%。设计价值。