首页> 外文会议>Annual SEMI Advanced Semiconductor Manufacturing Conference >Application of Residual Gas Analyzer(RGA) for Particle Reduction in ALD Oxide : DI: Defect Inspection and Reduction
【24h】

Application of Residual Gas Analyzer(RGA) for Particle Reduction in ALD Oxide : DI: Defect Inspection and Reduction

机译:残留气体分析仪(RGA)在ALD氧化物中还原颗粒的应用:DI:缺陷检查和还原

获取原文

摘要

Optimizing NF3 cleaning is crucial in minimizing defects seen in the process. In this paper, we took a different approach to maximize particle reduction using both conventional and non- conventional endpointing methods. Cleaning indicators, typically monitored during cleaning recipe, were also monitored during deposition. Implementation of additional purging significantly reduced remnants of cleaning byproducts during deposition. Our additional testing with reduction and dilution of NF3 flow showed improvements in cleaning efficiency. In this paper, we show that optimization of NF3 cleaning recipe using methods in addition to cleaning time optimization can reduce defects seen in the process.
机译:优化NF 3 清洁对于最大程度地减少过程中出现的缺陷至关重要。在本文中,我们采用了另一种方法来使用常规和非常规终点处理方法来最大程度地减少颗粒。通常在清洁配方期间监视的清洁指示剂,在沉积过程中也进行监视。实施额外的吹扫大大减少了沉积过程中清洁副产物的残留。我们对NF3流量进行了减少和稀释的附加测试表明,清洁效率得到了提高。在本文中,我们表明使用除清洁时间优化之外的方法优化NF3清洁配方还可以减少过程中出现的缺陷。