Electric light sources have been used to heat local tissues after orthopedic replantation surgery for extremities. The effectiveness of heat stress has been proven to aid the regeneration of injured skeletal muscle. Hyperthermic therapy is also used-in neonatal intensive care units. Unfortunately the application is done open-loop so that there is no indication of or control over the temperature of the skin. This can lead to burns if the temperature is too high or to ineffective treatment if the temperature is too low. A close-loop system was designed that allows the skin temperature to be held fixed. The temperature is measured from one to three sites using type K thermocouples attached to the skin. The temperature of the warmest site is controlled to within ±1.0 degree of 37C°. Allowing the skin to reach core temperature will increase blood flow to the treated area. The heat from the lamps is controlled via a PIC microcontroller interface between the thermocouples and a TRIAC. The TRIAC is used to control the electrical current supplied to the lamps.
机译:电光源已被用于在整形外科再生手术后加热局部组织的四肢。已经证明了热应激的有效性以帮助受伤的骨骼肌再生。高温治疗也用于新生儿重症监护单位。不幸的是,应用程序是开放的回路,使得在皮肤的温度下没有指示或控制。如果温度太低,这可能导致燃烧过高或者在治疗中无效。设计了封闭环系统,使皮肤温度固定。使用连接到皮肤的k热电偶从一到三个位置测量温度。最温暖的部位的温度控制在37°°的±1.0度范围内。允许皮肤达到核心温度会使血流增加到处理过的区域。来自灯的热量通过热电偶和三端双向可控硅之间的PIC微控制器接口控制。三折用于控制提供给灯的电流。