首页> 外文会议>International conference on medical image computing and computer-assisted intervention;MICCAI 2009 >In Vivo OCT Coronary Imaging Augmented with Stent Reendothelialization Score
【24h】

In Vivo OCT Coronary Imaging Augmented with Stent Reendothelialization Score

机译:体内OCT冠状动脉成像增强支架内血管内皮化评分

获取原文

摘要

The aim of this study is to automatically assess reendothelialization of stents at an accuracy of down to a few microns by analyzing endovascular optical coherence tomography (OCT) sequences. Vessel wall and struts are automatically detected and complete distance map is then computed from sparse distances measured between wall and struts by thin-plate spline (TPS) interpolation. A reendothelialization score is mapped onto the geometry of the coronary artery segment. Accuracy and robustness are increased by taking into account the inhomogeneity of datapoints and integrating in the same framework orthogonalized forward selection of support points, optimal selection of regu-larization parameters by generalized cross-validation (GCV) and rejection of detection outliers. The comparison against manual expert measurements for a phantom study and 12 in vivo stents demonstrates no significant discordance with variability of the order of the strut thickness.
机译:这项研究的目的是通过分析血管内光学相干断层扫描(OCT)序列,以低至几微米的精度自动评估支架的重新内皮化。自动检测容器壁和支柱,然后根据薄板样条(TPS)插值从壁和支柱之间测得的稀疏距离计算出完整的距离图。再内皮化分数被映射到冠状动脉节段的几何形状上。通过考虑数据点的不均匀性并将其集成在同一框架中,可以对支持点进行正交正向选择,通过广义交叉验证(GCV)进行最佳化参数的最佳选择以及拒绝检测异常值,从而提高了准确性和鲁棒性。与体模研究和12个体内支架的手动专家测量结果的比较表明,支杆厚度顺序的可变性没有显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号