首页> 外文会议>International conference on nuclear engineering;ICONE-16 >ANALYSIS OF A LOSS OF FEEDWATER CASE AT THE RINGHALS-3 NPP USING RELAP5/PARCS COUPLED CODES
【24h】

ANALYSIS OF A LOSS OF FEEDWATER CASE AT THE RINGHALS-3 NPP USING RELAP5/PARCS COUPLED CODES

机译:使用RELAP5 / PARCS耦合码分析RINGHALS-3 NPP的进水箱损失

获取原文

摘要

This paper deals with the development and validation of a coupled RELAP5/PARCS model of the Swedish Ringhals-3 pressurized water reactor against a Loss of Feedwater transient, which occurred on August 16, 2005.At first, the stand-alone RELAP5 and PARCS models are presented. All the 157 fuel assemblies are modeled in individually in both codes. The model is furthermore able to handle possible asymmetrical conditions of the flow velocity and temperature fields between the loops. On the neutronic side, the dependence of the material constants on history effects, burnup, and instantaneous conditions is accounted for, and the full heterogeneity of the core is thus taken into account. The reflectors are also explicitly represented. The coupling between the two codes is touched upon, with emphasis on the mapping between the hydrodynamic/heat structures and the neutronic nodes.The transient was initiated by a malfunction of the feedwater valve at the 2nd steam generator. Consequently, the turbines were tripped and, because of the low level in the SG-2 the reactor was scrammed. Activation of the auxiliary feedwater provided proper amount of cooling from the secondary side, resulting in safe shutdown conditions.Capabilities of the RELAP5 code were more challenged in this transient, where the influences of the feedback from the neutron kinetic side were also taken into account in theanalysis. The calculated values of the parameters show good agreement with the measured data.
机译:本文针对瑞典Ringhals-3压水堆的RELAP5 / PARCS耦合模型的开发和验证,该模型针对2005年8月16日发生的给水瞬态损失。 首先,介绍了独立的RELAP5和PARCS模型。这两个代码中的157个燃油组件均单独建模。该模型还能够处理环路之间的流速和温度场的可能不对称条件。在中子学方面,考虑了材料常数对历史效应,燃耗和瞬时条件的依赖性,因此考虑了核的完全异质性。反射器也被明确表示。涉及到两个代码之间的耦合,重点是流体动力/热结构与中子节点之间的映射。 过渡是由第二个蒸汽发生器的给水阀故障引起的。因此,涡轮机跳闸了,并且由于SG-2的液位低,反应堆被加料了。辅助给水的激活从次级侧提供了适量的冷却,从而确保了安全的停机条件。 在这种瞬态过程中,RELAP5代码的功能受到了更大的挑战,在瞬态过程中,还考虑了来自中子动力学侧反馈的影响。 分析。参数的计算值与测量数据显示出良好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号