首页> 外文会议>Conference on Vinyltec 2005: PVC in Building and Construction: Innovations, Applications, Additives and Properties; 20051003-05; Philadelphia,PA(US) >Measured Energy Savings and Demand Reduction from a Reflective Roof Membrane on a Large Retail Store in Austin
【24h】

Measured Energy Savings and Demand Reduction from a Reflective Roof Membrane on a Large Retail Store in Austin

机译:在奥斯丁的一家大型零售商店中通过反射性屋顶膜实现的节能量和减少的需求量

获取原文
获取原文并翻译 | 示例

摘要

In this study, we measured and documented summertime air-conditioning (a/c) daily energy savings and demand reduction from a reflective roof membrane retrofit on a large retail store in Austin, Texas. The original black rubber membrane was replaced with white thermoplastic resulting in a decrease in the average maximum roof surface temperature from 168℉ (76℃) to 126℉ (52℃). This building, with 100,000ft~2 (9300m~2) of roof area, yielded 3.6Wh/ft~2 (39Wh/m~2) in a/c average daily energy savings and 0.35W/ft~2 (3.8W/m~2) in average reduced demand. Total a/c annual abated energy and demand expenditures were estimated to be $7200 or 7.2c/ft~2 (77c/m~2). Based on cost data provided by the building manager, the payback is instantaneous with negligible incremental combined labor and material costs. The estimated present value of future abated expenditures ranged from $62,000 to $71,000 over the baseline 13 year service life of the roof membrane.
机译:在这项研究中,我们测量并记录了得克萨斯州奥斯汀一家大型零售商店的夏季空调(a / c)每天的节能量以及通过反射性屋顶膜改型所减少的需求。原来的黑色橡胶膜被白色热塑性塑料代替,导致平均最高屋顶表面温度从168℉(76℃)降低到126℉(52℃)。该建筑的屋顶面积为100,000ft〜2(9300m〜2),日均节能量为3.6Wh / ft〜2(39Wh / m〜2),日均节能量为0.35W / ft〜2(3.8W / m〜2)平均减少需求。每年的空调总能耗和需求支出估计为$ 7200或7.2c / ft〜2(77c / m〜2)。根据建筑经理提供的成本数据,投资回报是瞬时的,而人工和材料的总增量却可以忽略不计。在屋顶膜的基准13年使用寿命期间,未来减少的支出的估计现值在$ 62,000到$ 71,000之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号