首页> 外文会议>Computer and computing technologies in agriculture III >A New On-Line Detecting Apparatus of the Residual Chlorine in Disinfectant for Fresh-Cut Vegetables
【24h】

A New On-Line Detecting Apparatus of the Residual Chlorine in Disinfectant for Fresh-Cut Vegetables

机译:鲜切蔬菜消毒液中余氯在线检测新装置

获取原文
获取原文并翻译 | 示例

摘要

With the fast development of modern food and beverage industry, fresh-cut vegetables have wider application than before. During the process of sterilization in fresh-cut vegetables, the concentration of chloric disinfectant is usually so high that the common sensor can't be used directly on the product line. In order to solve this problem, we have invented a new detecting apparatus which could detect high concentration of chloric disinfectant directly. In this paper, the working principle, main monitor indicators, application and technical creations of the on-line apparatus have been discussed, and we also carried on the experimental analysis for its performance. The actual demands in factory could be met when the detecting flux is 2L/min, the dilution ratio is 15 and input amount of the disinfectant is 200ml per time, the max of the detecting deviation achieves ±4.8ppm(mg/L). The main detecting range of residual chlorine is 0~300ppm.
机译:随着现代食品和饮料工业的快速发展,鲜切蔬菜的应用比以前更加广泛。在鲜切蔬菜的消毒过程中,氯消毒剂的浓度通常很高,以至于普通传感器不能直接在生产线上使用。为了解决这个问题,我们发明了一种可以直接检测高浓度氯消毒剂的新型检测设备。本文讨论了在线仪器的工作原理,主要监测指标,应用和技术创新,并对其性能进行了实验分析。当检测通量为2L / min,稀释比为15,消毒剂输入量为200ml /次时,可以满足工厂的实际要求,最大检测偏差达到±4.8ppm(mg / L)。残留氯的主要检测范围是0〜300ppm。