【24h】

Design and performance test of a test rig for grain flow sensor

机译:谷物流量传感器测试台的设计和性能测试

获取原文
获取原文并翻译 | 示例

摘要

In order to develop a grain flow sensor, a test rig was built. Three weighting sensors were mounted on the weighting bin in the test rig to calibrate grain flow sensor and verify the accuracy of grain flow sensor. A valve plate was inserted in the bottom of the feed bin. The feed flow could be controlled by adjusting opening of the valve plate. A weighting measurement model and a feed flow model were established respectively according to user manual and calibration experiments. Weighting accuracy and feed rate for the test rig was analyzed through experiments. Results showed that the maximum relative error of weighting was 1.12%, the minimum relative error was 0.36%, and the average relative error was 0.61%. The average relative error of feed flow ranging from 0.5 to 2.4 kg/s was less than 4%. The test rig developed is stable and reliable, and meets the requirements for development and testing of the grain flow sensor.
机译:为了开发谷物流量传感器,建造了测试台。在测试装置的称重仓上安装了三个称重传感器,以校准谷物流量传感器并验证谷物流量传感器的准确性。将阀板插入进料仓的底部。进料流量可以通过调节阀板的开度来控制。根据用户手册和标定实验分别建立了权重测量模型和进料流量模型。通过实验分析了试验台的称重精度和进给速度。结果表明,加权的最大相对误差为1.12%,最小相对误差为0.36%,平均相对误差为0.61%。进料流量的平均相对误差范围为0.5至2.4 kg / s小于4%。开发的测试装置稳定可靠,满足谷物流量传感器的开发和测试要求。