Epiluminescence microscopy for the diagnosis of doubtful melanocytic skin lesions: Comparison of the ABCD rule of dermatoscopy and a new 7-point checklist based on pattern analysis

机译:用于诊断可疑黑素细胞性皮肤病变的发光显微镜:基于模式分析的皮肤镜检查的aBCD规则和新的7点检查表的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective: To compare the reliability of a new 7-point checklist based on simplified epiluminescence microscopy (ELM) pattern analysis with the ABCD rule of dermatoscopy and standard pattern analysis for the diagnosis of clinically doubtful melanocytic skin lesions. Design: In a blind study, ELM images of 342 histologically proven melanocytic skin lesions were evaluated for the presence of 7 standard criteria that we called the 'ELM 7-point checklist.' For each lesion, 'overall' and 'ABCD scored' diagnoses were recorded. From a training set of 57 melanomas and 139 atypical non-melanomas, odds ratios were calculated to create a simple diagnostic model based on identification of major and minor criteria for the '7-point scored' diagnosis. A test set of 60 melanomas and 86 atypical non-melanomas was used for model validation and was then presented to 2 less experienced ELM observers, who recorded the ABCD and 7-point scored diagnoses. Settings: University medical centers. Patients: A sample of patients with excised melanocytic lesions. Main Outcome Measures: Sensitivity, specificity, and accuracy of the models for diagnosing melanoma. Results: From the total combined sets, the 7-point checklist gave a sensitivity of 95% and a specificity of 75% compared with 85% sensitivity and 66% specificity using the ABCD rule and 91% sensitivity and 90% specificity using standard pattern analysis (overall ELM diagnosis). Compared with the ABCD rule, the 7-point method allowed less experienced observers to obtain higher diagnostic accuracy values. Conclusions: The ELM 7-point checklist provides a simplification of standard pattern analysis because of the low number of features to identify and the scoring diagnostic system. As with the ABCD rule, it can be easily learned and easily applied and has proven to be reliable in diagnosing melanoma.
机译:目的:比较基于简化的发光荧光显微镜(ELM)模式分析,ABCD皮肤镜检查规则和标准模式分析的新7点检查表的可靠性,以诊断临床上可疑的黑素细胞性皮肤病变。设计:在一项盲目研究中,评估了342种经组织学证实的黑素细胞性皮肤病变的ELM图像,以评估是否存在7个标准标准,我们将其称为“ ELM 7点检查表”。对于每个病变,记录“总体”和“ ABCD评分”诊断。从57个黑色素瘤和139个非典型非黑色素瘤的训练集中,计算出比值比,以基于对“ 7分评分”诊断的主要和次要标准的识别,创建一个简单的诊断模型。使用60个黑色素瘤和86个非典型非黑素瘤的测试集进行模型验证,然后提供给2个经验不足的ELM观察者,他们记录ABCD和7分评分诊断。地点:大学医疗中心。患者:切除了黑素细胞病变的患者样本。主要结果指标:黑色素瘤诊断模型的敏感性,特异性和准确性。结果:从总的组合集中,七点检查表的灵敏度为95%,特异性为75%,而使用ABCD规则的灵敏度为85%,特异性为66%,使用标准模式分析的灵敏度为91%,特异性为90% (整体ELM诊断)。与ABCD规则相比,七点方法允许经验不足的观察者获得更高的诊断准确性值。结论:ELM 7点检查表简化了标准模式分析,因为要识别的特征和评分诊断系统数量很少。与ABCD规则一样,它易于学习和应用,并且已被证明在诊断黑色素瘤方面是可靠的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号