首页> 外文OA文献 >Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology
【2h】

Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology

机译:使用湍流在线提取技术开发和验证血清25-羟基维生素D2 / D3的液相色谱 - 串联质谱分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Vitamin D is important to health and disease. Liquid chromatography-tandem mass spectrometry (LC-MSMS) is considered the most accurate technology for quantification of serum 25-hydroxyvitamin D (25OHD) which is the best biomarker for estimating vitamin D nutritional status. Methods: Serum was mixed with acetonitrile containing hexadeuterated 25-hydroxyvitamin D3 (d6-25OHD3) and centrifuged 10 min at 15,634×g. The supernatant was injected onto a turbulent flow preparatory column then transferred to a polar endcapped C18 analytical column. The mass spectrometer was set for positive atmospheric pressure chemical ionization. Results: The analytical cycle time was 5.5 min. Inter- and intra-assay CV for both analytes across three concentrations ranged from 3.8% to 14.2%. The method was linear from 3.0 to 283.6 nmol/L for 25-hydroxyvitamin D3 (25OHD3) and 4.6 to 277.9 nmol/L for 25-hydroxyvitamin D2 (25OHD2), with an accuracy of 88.7%–118.7% and 90.7%–100.3%, respectively. No carryover or ion suppression was observed. Comparison with a radioimmunoassay using patient specimens (n=527) showed a mean difference of 5.2%, and diagnostic agreement of 80.9% with Deming regression of slope 0.867, intercept 12.8, standard error of estimate (SEE) 17.4, and r=0.8425. Conclusions: The LC-MSMS method coupled with turbulent flow technology for serum 25OHD quantitation is rapid, efficient, and suitable for clinical testing. Clin Chem Lab Med 2009;47:1565–72.
机译:背景:维生素D对健康和疾病很重要。液相色谱-串联质谱(LC-MSMS)被认为是定量血清25-羟基维生素D(25OHD)的最准确技术,血清25-羟基维生素D是估计维生素D营养状况的最佳生物标志物。方法:将血清与含有六氘化25-羟基维生素D3(d6-25OHD3)的乙腈混合,并在15634×g下离心10分钟。将上清液注入湍流制备柱中,然后转移至极性封端的C18分析柱中。将质谱仪设置为正大气压化学电离。结果:分析循环时间为5.5分钟。三种浓度的两种分析物的测定间和测定内CV范围为3.8%至14.2%。该方法对于25-羟基维生素D3(25OHD3)为3.0至283.6nmol / L,对于25-羟基维生素D2(25OHD2)为4.6至277.9nmol / L,线性,准确度为88.7%–118.7%和90.7%–100.3% , 分别。没有观察到残留或离子抑制。与使用患者标本进行的放射免疫分析比较(n = 527)显示出平均差异为5.2%,诊断一致性为80.9%,戴明回归斜率为0.867,截距为12.8,估计标准误(SEE)为17.4,r = 0.8425。结论:LC-MSMS方法与湍流技术结合用于血清25OHD的定量分析是快速,高效的,并且适合临床测试。临床化学实验室杂志2009; 47:1565–72。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号