A simple and inexpensive method for the determination of various ionic species in different water matrices is discussed in this study. The approach is based on the employment of in-house-made capillary electrophoresis (CE) instruments with capacitively coupled contactless conductivity detection ((CD)-D-4), which can be realized even when only a modest financial budget and limited expertise are available. Advantageous features and considerations of these instruments are detailed following their pilot deployment in Vietnam. Different categories of ionic species, namely major inorganic cations (K+, Na+, Ca2+, Mg2+, and NH4+) and major inorganic anions (Cl-, NO3-, NO2-, SO42-, and phosphate), in different water matrices in Vietnam were determined using these in-house fabricated instruments. Inorganic trivalent arsenic (As(III)), which is the most abundant form of arsenic in reducing groundwater, was determined by CE-(CD)-D-4. The effect of some interfering ions in groundwater on the analytical performance was investigated and is highlighted. The results from in-house-made CE-(CD)-D-4-instruments were cross-checked with those obtained using the standard methods (AAS, AES, UV and IC), with correlation coefficients r(2) >= 0.9 and deviations from the referenced results less than 15%.
机译:本研究讨论了一种简单而廉价的测定不同水基质中各种离子种类的方法。该方法基于使用具有电容耦合非接触电导率检测((CD)-D-4)的内部毛细管电泳(CE)仪器,即使只有适度的财务预算和有限的专业知识,也可以实现该方法可用。这些工具的优势功能和考虑因素将在越南进行试点部署后详细介绍。在越南不同的水基质中,不同类别的离子物种分别为主要的无机阳离子(K +,Na +,Ca2 +,Mg2 +和NH4 +)和主要的无机阴离子(Cl-,NO3-,NO2-,SO42-和磷酸盐)。使用这些内部制造的仪器确定。 CE-(CD)-D-4测定了无机三价砷(As(III)),这是还原地下水中砷含量最高的形式。研究了地下水中某些干扰离子对分析性能的影响,并着重指出。将内部生产的CE-(CD)-D-4-仪器的结果与使用标准方法(AAS,AES,UV和IC)获得的结果进行交叉检查,相关系数r(2)> = 0.9与参考结果的偏差小于15%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号