The LCL grid-connected inverter has the ability to attenuate the high-frequency current harmonics. However, the inherent resonance of the LCL filter affects the system stability significantly. To damp the resonance effect, the dual-loop current control can be used to stabilize the system. The grid current plus capacitor current feedback system is widely used for its better transient response and high robustness against the grid impedance variations. While the weighted average current (WAC) feedback scheme is capable to provide a wider bandwidth at higher frequencies but show poor stability characteristics under weak grid scenarios. To overcome this shortcoming, the improved WAC damping method is proposed with an additional capacitor current feedback loop. In this paper, a systematic parameter design guideline for the optimal selection of the current loop PR controller and the additional capacitor current feedback coefficient are presented for the improved WAC feedback control strategy. The satisfactory range of the system control parameters can be obtained under different delay conditions to meet the system performance specifications. The improved WAC method enhances system robustness under weak grid scenarios, and the stability and robustness have been enhanced under control delay. Finally, the experimental results are presented to validate the effectiveness of the proposed improved WAC control strategy and the parameter design method. Analysis and Design of Improved Weighted Average Current Control Strategy for LCL-Type Grid-Connected Inverters. Available from: https://www.researchgate.net/publication/313734269_Analysis_and_Design_of_Improved_Weighted_Average_Current_Control_Strategy_for_LCL-Type_Grid-Connected_Inverters [accessed Apr 20, 2017].
机译:LCL并网逆变器具有衰减高频电流谐波的能力。但是,LCL滤波器的固有谐振会显着影响系统稳定性。为了抑制共振效应,可以使用双回路电流控制来稳定系统。电网电流加电容器电流反馈系统因其更好的瞬态响应和对电网阻抗变化的高鲁棒性而被广泛使用。虽然加权平均电流(WAC)反馈方案能够在更高的频率下提供更宽的带宽,但在弱电网情况下显示出较差的稳定性。为了克服这个缺点,提出了一种改进的WAC阻尼方法,该方法带有一个附加的电容器电流反馈环路。在本文中,针对改进的WAC反馈控制策略,提出了用于电流环路PR控制器最佳选择的系统参数设计指南以及附加的电容器电流反馈系数。可以在不同的延迟条件下获得令人满意的系统控制参数范围,以满足系统性能规格。改进的WAC方法增强了弱电网情况下的系统鲁棒性,并且在控制延迟下增强了稳定性和鲁棒性。最后,给出了实验结果,以验证所提出的改进的WAC控制策略和参数设计方法的有效性。 LCL型并网逆变器的改进加权平均电流控制策略分析与设计。可从以下网址获得:https://www.researchgate.net/publication/313734269_Analysis_and_Design_of_Improved_Weighted_Average_Current_Control_Strategy_for_LCL-Type_Grid-Connected_Inverters [2017年4月20日访问]。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号