首页> 外文OA文献 >Liquid-liquid equilibrium phase diagrams of new aqueous two-phase systems : Ucon 50-HB5100 + Ammonium Sulfate + water, Ucon 50-HB5100 + Poly(vinyl alcohol) + water, Ucon 50-HB5100 + Hydroxypropyl Starch + water, and Poly(ethylene glycol) 8000 + Poly(vinyl alcohol) + water
【2h】

Liquid-liquid equilibrium phase diagrams of new aqueous two-phase systems : Ucon 50-HB5100 + Ammonium Sulfate + water, Ucon 50-HB5100 + Poly(vinyl alcohol) + water, Ucon 50-HB5100 + Hydroxypropyl Starch + water, and Poly(ethylene glycol) 8000 + Poly(vinyl alcohol) + water

机译:新的水相两相系统的液-液平衡相图:Ucon 50-HB5100 +硫酸铵+水,Ucon 50-HB5100 +聚乙烯醇+水,Ucon 50-HB5100 +羟丙基淀粉+水和聚(乙二醇)8000 +聚乙烯醇+水

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The phase diagrams of Ucon 50-HB-5100 (Ucon) + ammonium sulfate (NH4)(2)SO4 + water, Ucon 50-HB-5100 + poly(vinyl alcohol) 10000 (PVA 10000) + water, Ucon 50-HB-5100 + hydroxypropyl starch (Reppal PES 100) + water, and poly(ethylene glycol) 8000 (PEG 8000)-PVA 10000 systems were determined at 22 degreesC. Measurements at 30 and 40 degreesC were also done for each Ucon-salt system. A linear regression was used to calculate the slope and standard deviation for each tie line. The standard deviations are in most situations lower than 0.1, and the tie-line slopes for each phase diagram vary within 5.5% around the medium value for all cases with the exception of the Ucon + (NH4)(2)SO4 + water system at 40 degreesC. The phase diagrams of the Ucon + (NH4)(2)SO4 + water system at different temperatures were shown to have a smaller amount of salt and polymer than conventional systems and to be thermoseparating, versatile, and particularly attractive, since phase formation is temperature-dependent. The phase diagrams of Ucon + PVA 10000 + water, Ucon + PES + water, and PEG + PVA 10000 + water systems were very similar, since high polymer concentrations (PES or PVA 10000) are required to form the two phases.
机译:Ucon 50-HB-5100(Ucon)+硫酸铵(NH4)(2)SO4 +水,Ucon 50-HB-5100 +聚乙烯醇10000(PVA 10000)+水,Ucon 50-HB的相图在22°C下测定-5100 +羟丙基淀粉(Reppal PES 100)+水和聚(乙二醇)8000(PEG 8000)-PVA 10000体系。每个Ucon-盐系统也都在30和40摄氏度下进行了测量。使用线性回归来计算每个连接线的斜率和标准偏差。在大多数情况下,标准偏差均小于0.1,所有情况下,除了Ucon +(NH4)(2)SO4 +水系统外,每个相图的联系线斜率在所有情况下均围绕中间值变化在5.5%以内40℃。 Ucon +(NH4)(2)SO4 +水系统在不同温度下的相图显示,盐和聚合物的量比常规系统少,并且由于相形成是温度变化,因此具有热分离性,通用性和特别的吸引力-依赖。 Ucon + PVA 10000 +水,Ucon + PES +水和PEG + PVA 10000 +水系统的相图非常相似,因为需要高浓度的聚合物(PES或PVA 10000)才能形成两相。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号