Pyrazinamide (PZA) is an important first-line antituberculosis drug because of its sterilizing activity against semidormant tubercle bacilli. In spite of its very high in vivo activity, its in vitro activity is not apparent unless an acidic environment is available, which makes PZA susceptibility testing difficult by conventional methods. The present study was, therefore, planned to assess the performance of the colorimetric BacT/ALERT 3D system and compare the results with those from conventional tests, i.e., the Löwenstein-Jensen (LJ) proportion method (pH 4.85) and Wayne's pyrazinamidase (PZase) assay, using 107 clinical isolates. The concordance among all of these tests was 89.71% after the first round of testing and reached 92.52% after resolution of the discordant results by retesting. Prolonged incubation of the PZase tube for up to 10 days was found to increase the specificity of the PZase test. The concordances between LJ proportion and BacT/ALERT 3D, LJ proportion and the PZase assay, and BacT/ALERT 3D and the PZase assay were found to be 99.06%, 93.46%, and 92.52%, respectively. Using the LJ results as the gold standard, the sensitivities of BacT/ALERT 3D and the PZase assay were 100 and 82.85%, respectively, while the specificity was 98.61% for both of the tests. The difference between the sensitivities of BacT/ALERT 3D and the PZase assay was significant (P = 0.025). The mean turnaround times for the detection of resistant and susceptible results by BacT/ALERT 3D were 8.04 and 11.32 days, respectively. While the major limitations associated with the PZase assay and the LJ proportion method are lower sensitivity in previously treated patients and a longer time requirement, respectively, the BacT/ALERT 3D system was found to be rapid, highly sensitive, and specific.
机译:吡嗪酰胺(PZA)由于对半休眠结节杆菌具有杀菌活性,因此是一种重要的一线抗结核药物。尽管其体内活性非常高,但除非有酸性环境,否则其体外活性并不明显,这使常规方法难以进行PZA敏感性测试。因此,本研究计划评估比色BacT / ALERT 3D系统的性能,并将结果与​​常规测试(即Löwenstein-Jensen(LJ)比例法(pH 4.85)和Wayne吡嗪酰胺酶(PZase))的结果进行比较。 )分析,使用107种临床分离株。在第一轮测试之后,所有这些测试的一致性为89.71%,在通过重新测试解决不一致结果之后达到了92.52%。发现将PZase管延长孵育长达10天会增加PZase测试的特异性。 LJ比例与BacT / ALERT 3D,LJ比例与PZase分析之间的一致性,BacT / ALERT 3D与PZase分析之间的一致性分别为99.06%,93.46%和92.52%。使用LJ结果作为金标准,BacT / ALERT 3D和PZase测定的灵敏度分别为100和82.85%,而两种测试的特异性均为98.61%。 BacT / ALERT 3D和PZase分析的灵敏度之间存在显着差异(P = 0.025)。 BacT / ALERT 3D检测耐药和易感结果的平均周转时间分别为8.04天和11.32天。尽管与PZase测定法和LJ比例法相关的主要限制分别是先前接受治疗的患者灵敏度较低和需要较长时间,但是BacT / ALERT 3D系统被认为是快速,高度灵敏和特异的。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号