Technical Notes: A Comparison of Two Saturated Hydraulic Conductivity Measuring Techniques in Relation to Drain Installation Methods

机译:技术说明:两种饱和水力传导率测量技术与排水装置安装方法的比较

摘要

Saturated hydraulic conductivity (Ks) is an important parameter influencing subsurface drainage design and performance, and Ks can be affected by subsurface drain installation methods. Ks was measured at a field site at Nashua, Iowa, with 1.2-m (4-ft) deep drain lines installed with a trenchless plow and with a chain trencher at four depths [0 to 150, 150 to 450, 450 to 750, 750 to 1000 mm (0 to 6, 6 to 18, 18 to 30, 30 to 40 in.)] using the Guelph permeameter (in situ technique) and the constant head permeameter method (laboratory technique) on undisturbed soil cores which were removed from the field site. Ks values were 10 to 130 times greater for the constant head permeameter compared to the Guelph permeameter method and were significantly different at all depths for the two measurement methods. The laboratory technique yielded greater standard deviation values for all depths, whereas the coefficient of variation values were greater for the in situ technique. Drain line installation methods did not significantly affect Ks at the 0 to 150 and 150 to 450 mm (0 to 6 and 6 to 18 in.) depths; however, at the 450 to 750 and 750 to 1000 mm (18 to 30 and 30 to 40 in.) depths, the trencher installation method had Ks values two to three times greater than the trenchless installation method and these differences were significantly different. Subsurface drain line installation method can affect the Ks values particularly near the drain line depths; however, these affects did not affect drainage system performance 10 years after installation.
机译:饱和导水率(Ks)是影响地下排水设计和性能的重要参数,并且Ks可能受地下排水安装方法的影响。 Ks是在爱荷华州纳舒厄(Nashhua)的现场测量的,排水深度为1.2米(4英尺),安装了无挖沟犁和链式挖沟机,挖沟深度为四个深度[0至150、150至450、450至750, 750至1000毫米(0至6、6至18、18至30、30至40英寸)使用Guelph渗透仪(原位技术)和恒压头渗透仪方法(实验室技术)在未受扰动的土壤芯上取下从现场。与Guelph渗透仪相比,恒定水头渗透仪的Ks值高10到130倍,并且两种测量方法在所有深度处的Ks值均显着不同。实验室技术在所有深度下产生的标准偏差值都更大,而原位技术的变异系数值则更大。排水管的安装方法在0到150毫米和150到450毫米(0到6毫米和6到18英寸)深度处对Ks没有明显影响;但是,在450到750和750到1000毫米(18到30和30到40英寸)的深度下,开沟器的安装方法的Ks值比无开槽的安装方法大2到3倍,并且这些差异明显不同。地下排水管的安装方法会影响Ks值,尤其是在排水管深度附近。但是,这些影响在安装10年后并未影响排水系统的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号