首页> 外文OA文献 >A multi-scale cardiovascular system model can account for the load-dependence of the end-systolic pressure-volume relationship.
【2h】

A multi-scale cardiovascular system model can account for the load-dependence of the end-systolic pressure-volume relationship.

机译:多尺度心血管系统模型可以说明收缩末期压力-容积关系的负荷依赖性。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

ABSTRACT: BACKGROUND: The end-systolic pressure-volume relationship is often considered as a load-independent property of the heart and, for this reason, is widely used as an index of ventricular contractility. However, many criticisms have been expressed against this index and the underlying time-varying elastance theory: first, it does not consider the phenomena underlying contraction and second, the end-systolic pressure volume relationship has been experimentally shown to be load-dependent. METHODS: In place of the time-varying elastance theory, a microscopic model of sarcomere contraction is used to infer the pressure generated by the contraction of the left ventricle, considered as a spherical assembling of sarcomere units. The left ventricle model is inserted into a closed-loop model of the cardiovascular system. Finally, parameters of the modified cardiovascular system model are identified to reproduce the hemodynamics of a normal dog. RESULTS: Experiments that have proven the limitations of the time-varying elastance theory are reproduced with our model: (1) preload reductions, (2) afterload increases, (3) the same experiments with increased ventricular contractility, (4) isovolumic contractions and (5) flow-clamps. All experiments simulated with the model generate different end-systolic pressure-volume relationships, showing that this relationship is actually load-dependent. Furthermore, we show that the results of our simulations are in good agreement with experiments. CONCLUSIONS: We implemented a multi-scale model of the cardiovascular system, in which ventricular contraction is described by a detailed sarcomere model. Using this model, we successfully reproduced a number of experiments that have shown the failing points of the time-varying elastance theory. In particular, the developed multi-scale model of the cardiovascular system can capture the load-dependence of the end-systolic pressure-volume relationship.
机译:摘要:背景:收缩末期压力-体积关系通常被认为是心脏的负荷独立属性,因此,它被广泛用作心室收缩的指标。但是,已经对该指标和时变弹性理论提出了许多批评:首先,它没有考虑收缩的现象;其次,已经通过实验证明了收缩末期压力体积关系与负荷有关。方法:代替时变弹性理论,使用肌节收缩的微观模型来推断左心室收缩产生的压力,这被认为是肌节单元的球形组装。将左心室模型插入心血管系统的闭环模型中。最后,确定修改后的心血管系统模型的参数,以重现正常狗的血液动力学。结果:已经证明时变弹性理论的局限性的实验在我们的模型中得以再现:(1)前负荷减少,(2)后负荷增加,(3)具有增加的心室收缩力的相同实验,(4)等容收缩和(5)流量钳。用该模型模拟的所有实验均产生不同的收缩末期压力-容积关系,表明该关系实际上与负荷有关。此外,我们证明了仿真结果与实验结果非常吻合。结论:我们实施了心血管系统的多尺度模型,其中通过详细的肌节模型描述了心室收缩。使用该模型,我们成功地再现了许多实验,这些实验显示了时变弹性理论的失败点。尤其是,开发的心血管系统多尺度模型可以捕获收缩末期压力-容积关系的负荷依赖性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号