首页> 外文OA文献 >Evaporative light scattering detector in normal-phase high-performance liquid chromatography determination of FAME oxidation products
【2h】

Evaporative light scattering detector in normal-phase high-performance liquid chromatography determination of FAME oxidation products

机译:蒸发光散射检测器在正相高效液相色谱法中测定FAME氧化产物

摘要

The use of an ELS detector in NP-HPLC for quantitative analysis of oxidation products in FAME obtained from oils is evaluated in this study. The results obtained have shown that the ELS detector enables the quantitative determination of the hydroperoxides of oleic and linoleic acid methyl esters as a whole, and connected in series with a UV detector makes it possible to determine both groups of compounds by difference, providing useful complementary information. The limits of detection (LOD) and quantification (LOQ) found for hydroperoxides were respectively 2.5 and 5.7μgmL -1 and precision of quantitation expressed as coefficient of variation was lower than 10%. Due to a low sensitivity the ELS detector shows limitations to determine the low contents of secondary oxidation products in the direct analysis of FAME oxidized at low or moderate temperature. Analysis of FAME samples obtained either from high linoleic sunflower oil (HLSO) or high oleic sunflower oil (HOSO) and oxidized at 80°C showed that only ketodienes formed from methyl linoleate can be determined in samples with relatively high oxidation, being the LOD and LOQ 0.2 and 0.4mg/g FAME, respectively, at the analytical conditions applied. The ELS detector also enabled the determination of methyl cis-9,10-epoxystearate and methyl trans-9,10-epoxystearate, which were resolved at the chromatographic conditions applied. Results showed that these compounds, which are formed from methyl oleate, were not detected in the high-linoleic sample, but occurred at non-negligible levels in the oxidized FAME obtained from HOSO. © 2012 Elsevier B.V.
机译:在这项研究中,评估了在NP-HPLC中使用ELS检测器定量分析从油中获得的FAME中的氧化产物。所获得的结果表明,ELS检测器能够定量测定整个油酸和亚油酸甲酯的氢过氧化物,并且与UV检测器串联可通过差值确定两组化合物,从而提供有用的补充信息。氢过氧化物的检出限(LOD)和定量限(LOQ)分别为2.5和5.7μgmL-1,以变异系数表示的定量精度低于10%。由于灵敏度低,ELS检测器在直接分析在低温或中温下氧化的FAME时,无法确定次级氧化产物的含量低。对从高亚油酸葵花籽油(HLSO)或高油酸葵花籽油(HOSO)中获得并在80°C氧化的FAME样品进行的分析表明,在较高氧化度的样品中只能测定亚油酸甲酯形成的酮二烯,即LOD和在所应用的分析条件下,LOQ分别为0.2和0.4mg / g FAME。 ELS检测器还能够测定顺式9,10-环氧硬脂酸甲酯和反式9,10-环氧硬脂酸甲酯,在所应用的色谱条件下可以分离。结果表明,这些由油酸甲酯形成的化合物在高亚油酸样品中未检出,但在从HOSO获得的氧化FAME中以不可忽略的水平存在。 ©2012 Elsevier B.V.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号