We report here results from a United Kingdom National Quality Assessment Scheme (UK NEQAS) exercise in which both plasma spiked with monoclonal antibodies and plasma from a patient known to have lupus anticoagulant (LA) were distributed to 245 hemostasis laboratories with a request for them to test for possible LA using their routine screening procedure. In general, good agreement was seen in the diagnosis of samples spiked with monoclonal antibodies against beta2-glycoprotein 1 (beta2GP1) and prothrombin, the LA-positive patient sample, and a normal pooled plasma; over 87% of centers correctly identified each sample. However, methods employing platelet neutralizing procedures were associated with a higher proportion of false-negative responses with the antiprothrombin-spiked sample, and it is important to recognize that sensitivity and responsiveness of different methods may vary between artificial plasmas and different LA-positive patient plasmas.
机译:我们在此报告英国国家质量评估计划(UK NEQAS)的一项研究结果,该研究将掺有单克隆抗体的血浆和已知患有狼疮抗凝剂(LA)的患者的血浆分配给245个止血实验室,要求他们使用他们的常规筛查程序测试可能的LA。通常,在诊断掺有针对β2-糖蛋白1(beta2GP1)和凝血酶原的单克隆抗体的样本,LA阳性患者样本和正常合并血浆中,可以发现良好的一致性。超过87%的中心正确识别了每个样本。但是,采用血小板中和程序的方法与抗凝血酶原加标样品的假阴性反应比例更高,因此重要的是要认识到,不同方法的灵敏度和响应度在人工血浆和不同的LA阳性患者血浆之间可能会有所不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号