This paper presents an overview of results fromexperimental research conducted at FSEC's FlexibleRoofing Facility in the summer of 2002. The FlexibleRoof Facility (FRF) is a test facility in Cocoa, Floridadesigned to evaluate a combination of five roofingsystems against a control roof using dark shingles.The intent of the testing is to evaluate how roofingsystems impact residential cooling energy use.Recent testing emphasizes evaluation of howincreasingly popular metal roofing systems, bothfinished and unfinished, might compare with othermore traditional roofing types.All of the test cells had R-19 insulation installedon the attic floor except in the double roofconfiguration which had R-19 of open cell foamblown onto the underside of the roof decking. Thetest results were used to determine relative thermalperformance of various roofing systems under typicalFlorida summer conditions. Measured impactsincluded changes to ceiling heat flux and attic airtemperature which influences loads from unintendedattic air leakage and duct heat gain. We also developan analysis method to estimate total cooling energybenefits of different roofing systems considering thevarious impacts.The results show that all the options performbetter than dark composition shingles. White metalperforms best with an estimated cooling energyreduction of about 15%, but the spectrally selectivemetal shingles (12%) and unfinished Galvalumeroofs (11%) do surprisingly well. Galvanized roofingdid less well than Galvalume (7% reduction) andworse performance in the second year of exposurewas observed due to corrosion of the zinc surface.The sealed attic with a double roof produced anestimated cooling energy reduction of only 2% --largely due to increases in ceiling flux.
机译:本文概述了2002年夏季在FSEC的FlexofRoofing Facility上进行的实验研究的结果。FlexibleRoofFacility(FRF)是位于佛罗里达州可可的测试设施,旨在使用深色木瓦评估五个屋面系统与对照屋顶的组合。测试的目的是评估屋面系统如何影响住宅的制冷能源使用。最近的测试强调评估越来越流行的金属屋面系统(已完成和未完成)是否可以与其他传统屋面类型进行比较。所有测试单元均在其安装了R-19绝缘阁楼地板,但在双层屋顶配置中,R-19的开孔泡沫被吹到屋顶地板的下侧。测试结果用于确定典型的佛罗里达夏季条件下各种屋面系统的相对热性能。测得的影响包括天花板热通量和阁楼气温的变化,这些变化会由于意外的空气泄漏和管道热增益而影响负荷。考虑到各种影响,我们还开发了一种分析方法来估算不同屋面系统的总冷却能效。结果表明,所有选择的性能都优于深色组成的木瓦。白色金属表现最佳,估计可减少约15%的冷却能量,但是光谱选择性金属带状板(12%)和未完成的Galvalumeroofs(11%)的效果令人惊讶。镀锌的屋面不如Galvalume(减少7%),并且由于锌表面的腐蚀,在暴露的第二年观察到的性能更差。带双屋面的密封阁楼估计冷却能仅减少2%,这主要是由于增加了在天花板通量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号