首页> 外文OA文献 >Steps toward accurate large-area analyses of Genesis solar wind samples: evaluation of surface cleaning methods using total reflection X-ray fluorescence spectrometry
【2h】

Steps toward accurate large-area analyses of Genesis solar wind samples: evaluation of surface cleaning methods using total reflection X-ray fluorescence spectrometry

机译:迈向Genesis太阳风样品的精确大面积分析的步骤:使用全反射X射线荧光光谱法评估表面清洁方法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Total reflection X-ray fluorescence spectrometry (TXRF) was used to analyze residual surface contamination on Genesis solar wind samples and to evaluate different cleaning methods. To gauge the suitability of a cleaning method, two samples were analyzed following cleaning by lab-based TXRF. The analysis comprised an overview and a crude manual mapping of the samples by orienting them with respect to the incident X-ray beam in such a way that different regions were covered. The results show that cleaning with concentrated hydrochloric acid and a combination of hydrochloric acid and hydrofluoric acid decreased persistent inorganic contaminants substantially on one sample. The application of CO2 snow for surface cleaning tested on the other sample appears to be effective in removing one persistent Genesis contaminant, namely germanium. Unfortunately, the TXRF analysis results of the second sample were impacted by relatively high background contamination. This was mostly due to the relatively small sample size and that the solar wind collector was already mounted with silver glue for resonance ion mass spectrometry (RIMS) on an aluminium stub. Further studies are planned to eliminate this problem. In an effort to identify the location of very persistent contaminants, selected samples were also subjected to environmental scanning electron microscopy. The results showed excellent agreement with TXRF analysis.
机译:全反射X射线荧光光谱法(TXRF)用于分析Genesis太阳风样品上的残留表面污染并评估不同的清洁方法。为了评估清洁方法的适用性,在基于实验室的TXRF清洁后分析了两个样品。分析包括对样品的概述和粗略的手工映射,方法是将样品相对于入射的X射线束进行定向,以使其覆盖不同的区域。结果表明,用浓盐酸以及盐酸和氢氟酸的组合进行清洗,基本上可以减少一个样品上的持久性无机污染物。在其他样品上测试使用CO2雪进行表面清洁似乎可以有效去除一种持久的创世纪污染物,即锗。不幸的是,第二个样品的TXRF分析结果受到相对较高的背景污染的影响。这主要是由于样品量相对较小,并且太阳能集电器已经在铝桩上安装了用于共振离子质谱(RIMS)的银胶。计划进行进一步研究以消除此问题。为了确定非常持久的污染物的位置,还对选定的样品进行了环境扫描电子显微镜检查。结果与TXRF分析显示出极好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号