This paper presents a flux weakening algorithm for synchronous reluctance motors (SynRMs) based on parameters estimated at standstill. Recently, flux saturated motors have been studied. Flux saturation models were identified and look-up tables were generated based on the saturation model for maximum torque per ampere (MTPA) and flux weakening operations. The operation with tables would degrade the accuracy of operating points when the table size is not enough. The proposed method implements a flux weakening operation without tables, and the operating points are determined with voltages and currents on operating points. Therefore, the accuracy can be maintained. In addition, the computation time to generate the tables is not needed, so the initial commissioning process can be reduced. The proposed method consists of two parts: the determination of a flux weakening region and the modification of current references. The flux weakening region is determined by the angle between direction vectors along the constant torque and voltage decreasing directions in the d-q axis current plane. After identifying the flux weakening region, the current references are modified for flux weakening according to the direction vector and appropriate magnitude. The direction and magnitude are determined by the operating point of the currents and magnitude of the output voltage, respectively. Using the flux saturation model for SynRMs, the flux weakening direction can be determined accurately. As a result, flux weakening can be performed precisely. The experimental results prove the validity of the proposed method.
机译:本文介绍了基于静止估计的参数的同步磁阻电动机(SYNRMS)的磁通弱化算法。最近,已经研究了助焊剂饱和电机。识别焊剂饱和型号,并基于每个安培(MTPA)和磁通弱化操作的最大扭矩产生查找表。与表格的操作会在表格大小不够时降低操作点的准确性。所提出的方法实现无需表的磁通弱操作,并且在操作点上的电压和电流确定操作点。因此,可以保持精度。另外,不需要计算要生成表的计算时间,因此可以减少初始调试过程。所提出的方法包括两部分:测定磁通量弱化区域和电流参考的修改。通过沿着D-Q轴电流平面中的恒定扭矩和电压减小方向的方向矢量之间的角度来确定磁通弱化区域。在识别磁通弱化区域之后,根据方向向量和适当的幅度修改电流参考。方向和幅度分别由电流的操作点和输出电压的大小确定。使用Synrms的磁通饱和模型,可以精确地确定磁通弱化方向。结果,可以精确地执行助熔剂削弱。实验结果证明了该方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号