首页> 美国政府科技报告 >AN INVESTIGATION OF THE RELATIONSHIPS BETWEEN THE ATTENUATION OF EARPLUGS AND EARMUFFS WITH INCIDENT SOUND LEVEL FOR STEADY-STATE AND IMPULSE SOUNDS USING INSTRUMENTED CADAVER EARS
【24h】

AN INVESTIGATION OF THE RELATIONSHIPS BETWEEN THE ATTENUATION OF EARPLUGS AND EARMUFFS WITH INCIDENT SOUND LEVEL FOR STEADY-STATE AND IMPULSE SOUNDS USING INSTRUMENTED CADAVER EARS

机译:利用仪表式颅骨耳朵研究耳塞和EaRmUFFs衰减与稳态声音和脉冲声音之间关系的调查

获取原文

摘要

The linearity of attenuation with incident sound level of four types of earplug and four types of earmuff has been investigated using freshly prepared and instrumented cadaver ears. Pure tones and /3-octave bands of random noise in the frequency range 125 to 8000 Hz were employed as steady-state stimuli with sound pressure levels between 75 and 125 dB. Impulses having peak sound levels in the range 135 to 175 dB(p) were also presented. Attenuations were determined in terms of transmission loss and insertion loss, although only the latter parameter was used for comparison with results from other measurement procedures.

著录项

  • 作者

    A M Martin;

  • 作者单位
  • 年度 1977
  • 页码 1-73