首页> 美国政府科技报告 >Study of toluene rotary fluid management device and shear flow condenser performance for a space-based organic Rankine power system
【24h】

Study of toluene rotary fluid management device and shear flow condenser performance for a space-based organic Rankine power system

机译:天基有机朗肯电力系统甲苯旋转流体管理装置及剪切流冷凝器性能研究

获取原文

摘要

Management of two-phase fluid and control of the heat transfer process in microgravity is a technical challenge that must be addressed for an orbital Organic Rankine Cycle (ORC) application. A test program was performed in 1-g that satisfactorily demonstrated the two-phase management capability of the rotating fluid management device (RFMD) and shear-flow condenser. Operational tests of the RFMD and shear flow condenser in adverse gravity orientations, confirmed that the centrifugal forces in the RFMD and the shear forces in the condenser were capable of overcoming gravity forces. In a microgravity environment, these same forces would not have to compete against gravity and would therefore be dominant. The specific test program covered the required operating range of the Space Station Solar Dynamic Rankine Cycle power system. Review of the test data verified that: fluid was pumped from the RFMD in all attitudes; subcooled states in the condenser were achieved; condensate was pushed uphill against gravity; and noncondensible gases were swept through the condenser.