首页> 美国政府科技报告 >Calculation of the pressure rise in the cooling tube of a two-phase cooling system during a quench of an indirectly cooled superconducting magnet
【24h】

Calculation of the pressure rise in the cooling tube of a two-phase cooling system during a quench of an indirectly cooled superconducting magnet

机译:在间接冷却的超导磁体的淬火期间计算两相冷却系统的冷却管中的压力升高

获取原文

摘要

Large superconducting detector magnets are indirectly cooled with two-phase helium flowing in cooling tubes attached to the coil or its support structure. Large detector magnets often quench such that most of the magnet stored energy ends up as heat stored in the coil package. The time constant for energy deposition in the coil and support structure is often quite short. This paper presents a method for calculating the peak pressure rise in the magnet tow-phase cooling tube during a magnet quench. A comparison of calculated peak pressure rise and measured pressure rise for the PEP-4 solenoid is presented in this report.

著录项

相似文献