首页> 美国政府科技报告 >Further tests on liquid-nitrogen-cooled, thin silicon-crystal monochcromators using a focused wiggler synchrotron beam
【24h】

Further tests on liquid-nitrogen-cooled, thin silicon-crystal monochcromators using a focused wiggler synchrotron beam

机译:使用聚焦摇摆器同步加速器光束对液氮冷却的薄硅晶单色器进行进一步测试

获取原文

摘要

A newly designed, cryogenically cooled, thin Si crystal monochromator was tested at the European Synchrotron Radiation Facility (ESRF) beamline BL3. It exhibited less than 1 arcsec of thermal strain up to a maximum incident power of 186 W and average power density of 521 W/mm(sup 2). Data were collected for the thin (0.7 mm) portion of the crystal and for the thick (>25 mm) part. Rocking curves were measured as a function of incident power. With a low power beam, the Si(333) rocking curve at 30 keV for the thin and thick sections was < 1 arcsec FWHM at room temperature. The rocking curve of the thin section increased to 2.0 arcsec when cooled to 78 K, while the thick part was unaffected by the reduction in temperature. The rocking curve of the thin section broadened to 2.5 arcsec FWHM and that of the thick section broadened to 1.7 arcsec at the highest incident power. The proven range of performance for this monochromator has been extended to the power density, but not the absorbed power, expected for the Advanced Photon Source (APS) undulator A in closed-gap operation (first harmonic at 3.27 keV) at a storage-ring current of 300 mA.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号