The performance of an idealized geothermal binary-fluid-cycle energy conversion system is shown to be a function of the temperatures of brine and working fluid leaving the heat exchanger. System power output, heat exchanger area required and initial well and heat exchanger costs are determined for counterflow, single and multi-pass parallel-counterflow exchangers. Results are presented graphically as functions of the brine and working fluid exit temperatures from the exchanger. Use of the system analysis developed is illustrated by showing quantitatively the advantage of the counterflow over the other flow arrangements considered. (ERA citation 02:000514)