首页> 美国政府科技报告 >Experimental Investigation of Cooling by Top Spray and Bottom Flooding of a Simulated 64 Rod Bundle for a BWR. Pt. 2. Main Experiment with Modified Test Section
【24h】

Experimental Investigation of Cooling by Top Spray and Bottom Flooding of a Simulated 64 Rod Bundle for a BWR. Pt. 2. Main Experiment with Modified Test Section

机译:BWR模拟64杆束顶喷和底浸冷却实验研究。铂。 2.改进测试部分的主要实验

获取原文

摘要

The cooling of an electrically heated, full scale 64-rod bundle has been investigated under simulated emergency core cooling conditions. Emphasis was laid on measurements of rod cladding and canister temperatures. By means of difference pressure measurements the levels in bundle, by-pass and downcomer could be estimated and thus the effective reflooding velocity. The test section was modified compared to the pre-tests, in order to improve system effects simulation. A new rod bundle was installed including a hollow, water, rod and 63 indirectly heated rods. Parameter effects of coolant mass flow rate and distribution, initial cladding temperature, pressure and power were studied. The effect of the way the test section was vented was also investigated and turned out to be very significant. (Atomindex citation 10:491865)