首页> 美国政府科技报告 >Demonstration of EIC'S Copper Sulfate Process for Removal of Hydrogen Sulfide and Other Trace Contaminants from Geothermal Steam at Turbine Inlet Temperatures and Pressures. Final Report
【24h】

Demonstration of EIC'S Copper Sulfate Process for Removal of Hydrogen Sulfide and Other Trace Contaminants from Geothermal Steam at Turbine Inlet Temperatures and Pressures. Final Report

机译:EIC硫酸铜工艺在涡轮机进口温度和压力下从地热蒸汽中去除硫化氢和其他痕量污染物的证明。总结报告

获取原文

摘要

The results obtained during the operation of an integrated, one-tenth commercial scale pilot plant using EIC's copper sulfate process for the removal of hydrogen sulfide and other contaminants from geothermal steam at turbine upstream conditions are discussed. The tests took place over a six month period at Pacific Gas and Electric Company's Unit No. 7 at The Geysers Power Plant. These tests were the final phase of a development effort which included the laboratory research and engineering design work which led to the design of the pilot plant. Broadly, the objectives of operating the pilot plant were to confirm the preliminary design criteria which had been developed, and provide data for their revisions, if appropriate, in a plant which contained all the elements of a commercial process using equipment of a size sufficient to provide valid scale-up data. The test campaign was carried out in four phases: water testing; open circuit, i.e., non integrated scrubbing, liquid-solid separation and regeneration testing; closed circuit short term; and closed circuit long term testing. (ERA citation 05:037977)