首页> 美国政府科技报告 >Effect of Electrical-Utility-System Voltage Harmonics on Induction Motors
【24h】

Effect of Electrical-Utility-System Voltage Harmonics on Induction Motors

机译:电气系统电压谐波对异步电动机的影响

获取原文

摘要

Distortion of the electrical utility system voltage waveform can result in damage to or malfunction of user electrical equipment. An experiment was carried out to determine the effect of utility voltage harmonics on the temperature rise of single-phase induction motors. The results suggest that utility voltage harmonics do not significantly affect the operating temperature of a single-phase induction motor until the amplitudes of the harmonics are much larger than the amplitudes currently present in the US utility system. (ERA citation 06:021819)