首页> 美国政府科技报告 >Preliminary Design Study of Compressed-Air Energy Storage in a Salt Dome. Volume 3. Design of the Air-Storage Cavern in Salt. Final Report
【24h】

Preliminary Design Study of Compressed-Air Energy Storage in a Salt Dome. Volume 3. Design of the Air-Storage Cavern in Salt. Final Report

机译:盐穹顶压缩空气储能初步设计研究。第3卷。盐中储气洞的设计。总结报告

获取原文

摘要

This report was prepared as a result of a contract between Middle South Services, Inc. and Fenix and Scisson, Inc. The conceptual design was prepared for two sites, Hazlehurst and Prothro as two known possible sites. It was later expanded to include a third site, Carmichael as the first two sites were not then available. This required the design and costing at various depths, 670 m (2200 ft), 488 m (1600 ft) and 1067 m (3500 ft) to the top of the cavern. It also involves variation in the size of the caverns for various weekly cycles of required air pressure to supply the turbine during peak load periods. The air is released from the caverns at 310 Kg/sec for eight hours per day, five days per week and the caverns replenished through compressors eight hours per day seven days per week. The pressure ranges from a maximum of 70 bars at the beginning of the week to 50 bars at the end of the generating period on Friday. The temperature of the input and outlet air is assumed to be 140 exp 0 C. This agrees with the estimated temperature of the cavern at Carmichael which allows for an isothermal operation. During preparation of the report no technical or environmental barriers were found. (ERA citation 07:043741)