首页> 美国政府科技报告 >Circulating water subsystem design description: 4 x 350 MW(t) Modular HTGR (High-Temperature Gas-Cooled Reactor) Plant
【24h】

Circulating water subsystem design description: 4 x 350 MW(t) Modular HTGR (High-Temperature Gas-Cooled Reactor) Plant

机译:循环水子系统设计说明:4 x 350 mW(t)模块化高温气冷堆(高温气冷堆)装置

获取原文

摘要

The Circulating Water System is a subsystem within the Heat Rejection Group (HRG). The Circulating Water System consists of two independent loops to remove waste heat from the turbine building closed cooling water system and from the condensers associated with each turbine generator set. In normal plant operation, circulating water is pumped from the cooling tower basin through the condensers and heat exchangers and back to the cooling tower where the waste heat is released to the atmosphere via mechanical draft cooling towers. The system consists of two flow paths with two half-size, vertical pumps associated with each path.