首页> 美国政府科技报告 >Peak-Power Measurements Using a Peak-Power Ratio Generator and a Dual-Channel, True-Power-Release Power Meter
【24h】

Peak-Power Measurements Using a Peak-Power Ratio Generator and a Dual-Channel, True-Power-Release Power Meter

机译:使用峰值功率比发生器和双通道,真功率释放功率计进行峰值功率测量

获取原文

摘要

A signal-processing module permits peak-power measurements on a dual-channel, true-power-response power meter. Operation is based on the constant peak-power output of a hybrid analog/digital loop. The peak current of a tunnel diode serves as the high-bandwidth, stable-reference levels for the loop. Measurement accuracy is +0, -0.35 dB for pulse widths of greater than or equal to6.7 ns and pulse repetition frequencies up to 75 MHz. Basic measurement range is from +10 to +36 dBm. Calibration is in terms of a known continuous-wave signal - typically +10 dBm. (ERA citation 11:034699)