Air quality monitoring is being conducted as part of remedial investigation activities at waste sites in the 1100-EM-1 Operating Unit at the US Department of Energy's Hanford Site. Sampling is being conducted for volatile organic compounds (VOCs), semivolatile organic compounds (SVOCs) (including pesticides and PCBs), metals, and asbestos. The monitoring program is being conducted in three phases: before, during, and after intrusive remedial investigation activities. At each waste site, battery-powered monitoring equipment is positioned at one location upwind of the site (to measure background concentrations of pollutants) and typically at two locations downwind of the site. Control samples are used to identify sample contamination that may occur during handling or analysis. All samples are analyzed using methods approved by the US Environmental Protection Agency. The results from the first phase of sampling have been assessed and are being used to upgrade sampling and laboratory analysis procedures. 5 refs.