Determination of Corrosion Inhibitor Criteria for Type III/IIIA Tanks During Salt Dissolution Operations Summary Document

机译:在盐溶解操作期间确定III / IIIa型罐的腐蚀抑制剂标准摘要文件

获取原文

摘要

Dissolution of salt from Type III/IIIA waste tanks at the Savannah River Site may create solutions with inhibitor concentrations below those currently required (0.6M OH sup - and 1.1M OH sup - + NO sub 2 sup -) per the Corrosion Control Program for high nitrate salt solutions (5.5 to 8.5M NO sub 3 sup -). An experimental program was conducted to evaluate the corrosion susceptibility of grade A537 carbon steel for waste simulants containing 4.5-8.5M NaNO sub 3 with maximum inhibitor concentrations of 0.6M NaOH and 0.2M NaNO(sub 2). These maximum inhibitor concentrations used in this program are at a reduced level from those currently required. Current requirements were initially established for the Types I, II and IV tanks made of A285 carbon steel. The experimental program involved corrosion testing to evaluate the pitting and stress corrosion stress corrosion cracking (SCC) susceptibility of the Type III/IIIA waste tank materials. The program was conducted in two phases; the results of the first phase were reported previously (WSRC-STI-2006-00029). In this second phase, the corrosion specimens were modified to represent the 'as-fabricated' condition of the tank wall, and included specimens with mill scale, ground welds and stress-relief heat treatments. The complete description of the corrosion testing and the results are reported herein.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号