摘要

Preliminary minimum detectable levels (MDLS) of selected actinide isotopes have been determined in full-scale, 55-gallon drums filled with a range of mock-waste materials from combustibles (0.14 g/CM(sup 3)) to sand (1.7 g/CM(sup 3)). Measurements were recorded from 100 to 10,000 seconds with selected actinide sources located in these drums at an edge position, on the center axis of a drum and midway between these two positions. Measurements were also made with a (sup 166)Ho source to evaluate the attenuation of these mock-matrix materials as a function of energy. By knowing where the source activity is located within a drum, our preliminary results show that a simply collimated 90% HPGE detector can differentiate between TRU (>100 nCi/g) and LLW amounts of (sup 239)Pu in only 100s of measurement time and with sufficient accuracy in both low and medium density, low Z materials. Other actinides measured so far include (sup 235)U, (sup 241)Am, and (sup 244)Cm. These measurements begin to establish the probable MDLs achievable in the nondestructive assays of real waste drums when using active and passive CT. How future measurements may differ from these preliminary measurements is also discussed.