首页> 美国政府科技报告 >Model-Based Probabilistic Inversion Framework for Wire Fault Detection Using TDR
【24h】

Model-Based Probabilistic Inversion Framework for Wire Fault Detection Using TDR

机译:基于模型的TDR线路故障检测概率反演框架

获取原文

摘要

Time-domain reflectometry (TDR) is one of the standard methods for diagnosing faults in electrical wiring and interconnect systems, with a long-standing history focused mainly on hardware development of both high-fidelity systems for laboratory use and portable hand-held devices for field deployment. While these devices can easily assess distance to hard faults such as sustained opens or shorts, their ability to assess subtle but important degradation such as chafing remains an open question. This paper presents a unified framework for TDR-based chafing fault detection in lossy coaxial cables by combining an S-parameter based forward modeling approach with a probabilistic (Bayesian) inference algorithm. Results are presented for the estimation of nominal and faulty cable parameters from laboratory data.